# Digital output

API calls for digital output control (built-in device outputs switching). Some device models work with `set_all` and some with `set` calls.

## API actions

API base path: `/tracker/output`.

### set\_all

Request to change the states of all digital outputs of the device. The device must be online.

**required sub-user rights:** `tracker_set_output`.

#### Parameters

| name        | description                                                                                                                       | type             | format                |
| ----------- | --------------------------------------------------------------------------------------------------------------------------------- | ---------------- | --------------------- |
| tracker\_id | ID of the tracker (aka "object\_id"). Tracker must belong to authorized user and not be blocked.                                  | int              | 999199                |
| outputs     | Array of desired states of all digital outputs, e.g. `[true, true, false]` means output 1 is on, output 2 is on, output 3 is off. | array of boolean | `[true, true, false]` |

#### Examples

cURL

{% code overflow="wrap" %}

```sh
curl -X POST 'https://api.eu.navixy.com/v2/tracker/output/set_all' \
    -H 'Content-Type: application/json' \
    -d '{"hash": "a6aa75587e5c59c32d347da438505fc3", "tracker_id": 265489, "outputs": [true, true, false]}'
```

{% endcode %}

#### Response

```json
{
 "success": true
}
```

#### Errors

* 204 – Entity not found - if there is no tracker with such ID belonging to authorized user.
* 208 – Device blocked - if tracker exists but was blocked due to tariff restrictions or some other reason.
* 213 – Cannot perform action: the device is offline - if corresponding tracker is not connected to the server.
* 214 – Requested operation or parameters are not supported by the device - if device does not support batch mode, or has\
  a different number of outputs.
* 219 – Not allowed for clones of the device - if tracker is clone.

### set

Request to change the state of the specified digital output of the device. The device must be online.

**required sub-user rights:** `tracker_set_output`.

#### Parameters

| name        | description                                                                                      | type    | format     |
| ----------- | ------------------------------------------------------------------------------------------------ | ------- | ---------- |
| tracker\_id | ID of the tracker (aka "object\_id"). Tracker must belong to authorized user and not be blocked. | int     | 999199     |
| output      | The number of the output to control, starting from 1.                                            | int     | 1          |
| enable      | `true` if the requested output should be enabled, or `false` if it should be disabled.           | boolean | true/false |

#### Examples

{% tabs %}
{% tab title="cURL" %}
{% code overflow="wrap" %}

```sh
curl -X POST 'https://api.eu.navixy.com/v2/tracker/output/set' \
    -H 'Content-Type: application/json' \
    -d '{"hash": "a6aa75587e5c59c32d347da438505fc3", tracker_id: 265489, "output": 1, "enable": true}'
```

{% endcode %}
{% endtab %}

{% tab title="HTTP GET" %}
{% code overflow="wrap" %}

```http
https://api.eu.navixy.com/v2/tracker/output/set?hash=a6aa75587e5c59c32d347da438505fc3&tracker_id=265489&output=1&enable=true
```

{% endcode %}
{% endtab %}
{% endtabs %}

#### Response

```json
{
 "success": true
}
```

#### Errors

* 204 – Entity not found - if there is no tracker with such ID belonging to authorized user.
* 208 – Device blocked - if tracker exists but was blocked due to tariff restrictions or some other reason.
* 213 – Cannot perform action: the device is offline - if corresponding tracker is not connected to the server.
* 214 – Requested operation or parameters are not supported by the device - if device does not support controlling single\
  output, does not have specified digital output, or the specified output reserved to "engine block" feature. In this\
  case, output cannot be controlled by this command for safety reasons.
* 219 – Not allowed for clones of the device - if tracker is clone.