Profile for Navixy TT-1.

{
    "type": <string>,           // can be "interval" (send tracking data based on time intervals), "distance" (send tracking data after passing specified distance)
    "psm_mode": <int>,          // power save mode, 0 - disable, 1 - powersave mode, 2 - Back-up Battery Power Saving Mode
    "tracking_interval": <int>, // optional, interval in seconds, e.g. 30 means that the device will send tracking data every 30 seconds
    "tracking_distance": <int>  // optional, distance in meters, e.g. 100 means that the device will send data every 100 meters
    "tracking_angle" : <int>,   // optional, if specified, the device will additionally send data when it changes direction to specified angle, e.g. 30 degrees
    "psm_interval": <int>,      // optional, Define the time interval in seconds (60-65535) which the unit stays in the sleeping state when powersave mode
    "bat_voltage": <string>,    // optional, Threshold of low back-up battery voltage
    "bat_psm_interval": <int>   // optional, sleeping duration when battery voltage below defined threshold, seconds
}